Skip to main content
Insights

How to Design Machine Guarding Around Pipework, Cable Trays and Services

Navigate Article

Machine guarding often needs to be installed around pipework, cable trays, ducts, electrical services, conveyors and building structures. These interfaces can create gaps that allow people to reach around, under or through the guard into hazardous machine movement.

The correct approach is not to cut panels around services wherever they happen to cross the perimeter. The guarding layout must still prevent or adequately restrict access to the actual danger zone, maintain suitable safety distances and allow the services to remain accessible for inspection and maintenance.

This is particularly important on retrofit projects, where existing utilities and structures may not align with the preferred guard perimeter. Modular machine guarding can help adapt the layout around these constraints, but standard panels and posts must not create uncontrolled openings.

Why Services Create Guarding Problems

Pipework, cable trays and other services can interrupt an otherwise continuous guarding perimeter.

Common examples include:

  • overhead cable trays crossing above or alongside the enclosure where the interface may create an opening or access path
  • pipework passing through side panels
  • electrical conduit entering guarded machine areas
  • extraction ducting near conveyors or processing equipment
  • compressed-air and hydraulic lines
  • machine-mounted control cabinets
  • cooling lines and drainage connections
  • structural steel, columns and wall-mounted services
  • fire-suppression pipework

A panel may look secure until a service penetration creates an opening beside, above or below it. That opening may provide access to rotating machinery, conveyor nip points, robot movement, press tooling or other hazards.

The risk is not determined by the size of the service alone. It depends on the opening dimensions, guard position, possible reach path and distance to the actual danger zone.

Start With the Machine Hazard, Not the Service Route

The guarding perimeter should be designed around the machine hazard first.

Identify:

  • hazardous moving parts and danger zones
  • machine operating envelope
  • robot movement, end effectors and carried loads
  • conveyor drives, rollers and transfer points
  • press, palletizer or packaging-machine movement
  • possible ejection or falling material
  • operator, maintenance and cleaning access
  • product and pallet transfer paths
  • required safety distances and controlled access points

Once the hazard layout is understood, identify where services cross or approach the proposed guard line.

Do not move the guarding closer to a hazard simply to avoid relocating pipework or cable trays. If the available space cannot maintain the required separation, the design may need an infill section, altered perimeter, local close-fitting guard or service modification.

Map Every Service Interface

Before fabrication or installation, prepare a layout showing the guarding perimeter and all relevant services.

Review:

  • pipe diameter and insulation thickness
  • cable-tray width, height and future capacity
  • conduit routes and junction boxes
  • ducts, extraction lines and flexible connections
  • access needed for valves, fittings and electrical work
  • service movement caused by vibration, thermal expansion or maintenance
  • floor penetrations and trench covers
  • wall and ceiling interfaces
  • potential leaks, washdown or drainage issues
  • future service additions or line expansion

The layout should distinguish between services that pass outside the guarded area and those that must penetrate the enclosure.

Where practical, route services outside the guarding perimeter or above the enclosure in a way that does not create an access path and still allows the service to be inspected, maintained and operated as required. Where penetration is unavoidable, it should be designed as a controlled interface rather than a field-cut opening.

Where fire-suppression, emergency lighting or other building safety systems are present, confirm that the guarding layout does not obstruct their required operation, inspection or maintenance.

Control Penetrations Through Guarding

A service penetration should be no larger than necessary for the required service, insulation, movement and maintenance access.

Consider:

  • clearance around the pipe, duct or cable tray
  • possible reach-through access around the penetration
  • gaps created by thermal movement or vibration
  • the location of the nearest hazard
  • whether flexible seals, collars or infill panels are suitable
  • whether a person could access the hazard from above, below or beside the service
  • whether the penetration creates a sharp edge, trapping point or cleaning problem
  • fire, hygiene or environmental requirements for the area

A pipe penetration that is acceptable near a nonhazardous section of a machine may be unsuitable near a conveyor drive, robot operating space or accessible nip point.

Where a service enters near hazardous movement, the guarding arrangement may require a shaped infill panel, fixed cover, tunnel section or local close-fitting guard. The solution should preserve the guarding function without obstructing service operation or maintenance.

Avoid Reach-Through and Reach-Around Gaps

Services often create irregular gaps that are missed during initial layout review.

Check for:

  • spaces between pipework and mesh panels
  • gaps beside cable trays and wall interfaces
  • openings above guards where trays cross the perimeter
  • floor gaps around conduits or drainage lines
  • access around ductwork and support brackets
  • gaps between service penetrations and machine frames
  • openings near conveyor supports or chutes
  • panel ends that stop short of a wall or column
  • removable service covers not correctly refitted

The question is not simply whether a person can fit through the opening. It is whether a hand, arm, leg or other body part can reach the danger zone through, around or beneath the guarding.

Where distance is used as the protective measure, the opening size and distance to the hazard must be assessed together.

Design for Maintenance Access

Services need maintenance too. A guarding arrangement should not force electricians, plumbers or maintenance teams to remove panels or enter a hazardous area unnecessarily.

Consider:

  • access to valves, isolators and disconnects
  • access to cable trays and junction boxes
  • pipe inspection and leak detection
  • replacement of filters, hoses or service components
  • access for cleaning around utility lines
  • lockout/tagout points and energy-isolating devices
  • removal of service covers
  • access for tools, carts or lifting equipment

Where service maintenance requires regular entry into a guarded area, provide a practical controlled access method. Where opening that access point could expose personnel to hazardous machine functions, an interlocked gate or other suitable safety arrangement may be required.

However, a service access opening should not become an informal personnel entry point. Its size, location and removal method should reflect the intended task.

Consider Washdown, Corrosion and Hygiene

In food processing, washdown and corrosive environments, service interfaces can create contamination traps or corrosion points.

Review:

  • open gaps around pipe penetrations
  • exposed insulation or damaged seals
  • water retention behind brackets or infill panels
  • difficult-to-clean spaces around services
  • corrosion beneath cable trays or pipe supports
  • compatibility of seals, gaskets and infill materials with cleaning chemicals
  • drainage around posts, base plates and penetrations
  • whether services prevent cleaning of both sides of the guard

For hygienic areas, avoid unnecessary holes, open-ended sections and inaccessible cavities. Required penetrations should be designed so they can be cleaned, inspected and maintained without compromising guarding performance.

Use Modular Guarding Without Forcing the Layout

Modular machine guarding can be useful around services because panels, posts and infill sections can be configured to suit irregular layouts.

Possible modular solutions include:

  • purpose-sized infill panels
  • shaped fixed panels around pipework
  • split-panel arrangements for removable service access
  • offset posts to avoid tray supports
  • overhead extensions below cable trays
  • tunnel sections around conveyors or service interfaces
  • controlled maintenance gates near isolators or service points

However, modular components should not be cut or modified on site without review. A field-cut panel can reduce strength, create sharp edges, weaken corrosion protection, affect supplier installation requirements or leave an opening that no longer controls access.

Where standard modular components cannot safely accommodate a service, a custom fabricated section may be needed.

Common Design Mistakes

Common mistakes include:

  • cutting a panel around pipework without checking reach paths
  • placing guards too close to hazards to avoid services
  • leaving oversized gaps around cable trays or ducts
  • ignoring future service additions
  • blocking access to isolation points or valves
  • creating inaccessible cleaning areas around penetrations
  • allowing service supports to become climbing points
  • leaving sharp cut edges around cable or pipe openings
  • using removable panels for frequent service access
  • failing to update drawings after service or guarding modifications

A service penetration is part of the safeguarding design. It should be reviewed with the same care as a gate, transfer opening or conveyor interface.

Conclusion

Designing machine guarding around pipework, cable trays and services requires a balance between hazard control, service access and practical installation.

The guarding perimeter must still control access to the machine danger zone, even where pipes, ducts, cables or structural constraints interrupt the layout. Penetrations should be minimized, positioned carefully and designed to prevent reach-through, reach-around or reach-under access.

Modular guarding can help adapt a perimeter around existing services, but standard panels should not dictate the final layout. If a service interface creates an uncontrolled gap, the design should be changed before installation.

Frequently Asked Questions

Can pipework pass through machine guarding?

Yes, but the penetration must be designed so it does not create an uncontrolled access path to hazardous machine movement. Opening size, service movement and distance to the danger zone should be assessed together.

How should cable trays be handled above machine guarding?

Cable trays should be positioned so they do not create reach-over access or uncontrolled gaps above the enclosure. Where a tray crosses the perimeter, the interface may need an extension panel, infill section or other controlled detail.

Can a guarding panel be cut around a pipe?

Sometimes, but field-cut modifications should not be made without review. The opening must maintain guard strength, controlled access, corrosion protection and the required safety distance.

Do service penetrations affect safety distance?

They can. A penetration may allow a person to reach closer to the hazard than the main panel arrangement permits. Opening size and distance to the actual danger zone must be assessed together.

Should services inside a guarded area have separate access?

Where services require regular inspection or maintenance, the guarding layout should provide a practical controlled access method. This may include an interlocked gate or a service opening designed for the intended task.

Can modular guarding work around cable trays and pipework?

Yes. Modular panels, posts and infill sections can often be configured around services. Where standard components cannot safely close an interface, a custom section may be required.

Request A Quote

Need Guarding for a Machine or Production Line?

  • Free, no obligation quote
  • Send drawings or a basic layout
  • Get a recommended configuration
  • 24-48 hours turnaround on quotes

Only PDF, DWG and DXF files may be uploaded. Please contact us if you have an alternative format.

MACHINE GUARDS DIRECT
We supply modular machine guarding and partitioning systems for industry including robotics, CNC machining and automated production lines. Designed for flexibility, fast installation and compliance.
We work with standards ISO 14120, AS 4024, OSHA 29 CFR 1910, and CE / EU Machinery Regulation and have supplied systems to the United States, Australia, Europe, and South East Asia.
Follow Us On LinkedIn